Customization: | Available |
---|---|
After-sales Service: | Within 1 Year |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | DST2305 | DST2505 | DST2106 | DST2156 | DST2206 | DST2306 | ||||
Max Loading(kN) | ±300 | ±500 | ±1000 | ±1500 | ±2000 | ±3000 | ||||
Test force accuracy | ±1.0% or ±0.5%(test range±2%~100%FS) | |||||||||
Actuator amplitude (mm) |
Standard ±75(optional±100,±150),The actual stroke is greater than 2 times the amplitude | |||||||||
Actuator structure | Double rod double acting | |||||||||
Displacement accuracy | ±0.5%FS | |||||||||
Optional fixture types | Mechanical Tension, Compression, Bending Grips, Hydraulic Chucks | Mechanical compression, bending clamps, hydraulic chucks | ||||||||
Optional test accessories | High and low temperature environmental box, high temperature furnace, confining pressure box | High and low temperature environmental box, high temperature furnace | ||||||||
Frequency range (Hz) | 0.001~25(or 0. 1~60) | 0.001~15(or 0. 1~30) | ||||||||
Test waveform | Sine wave, triangle wave, square wave, ramp wave, etc. User-end waveforms (pulse, half-sine, half-triangle, etc.) can be customized. | |||||||||
Width between columns (mm) |
700×500 | 850×500 | 900×700 | |||||||
Test space height (mm) |
1500(600) | 2000(600) | ||||||||
Dimensions(mm³) | 1100×900×2600 | 1400×1150×3000 | 1600×1400×3250 | |||||||
Recommended specifications of oil source | 36L/min, 45L/min, 70L/min,90L/min, 150L/min preset pressure 21Mpa |
|||||||||
Notice |
|