CXRW-300CT Vicat Softening Temperature Tester with Computer for plastics , rubber, nylon and electric insulator
Usage : Mainlyused for determination of Heat Deflection Temperature (HDT) and Vicat Softening Point (VST) Temperature for thermoplastics material like plastics , rubber, nylon and electric insulator
Standards Complied: GB/T 1634.1, GB/T-1634.2-2004 latest standard , GB/T 8802-2001 determination of Vicat Softening Point temperature for thermoplastics pipe and accessories, ISO 2570 Determination of Vicat Softening Point temperature for PVC pipe and GB/T 1633 , ISO 75-1997(E), ISO 306-1987(E). ASTM D1525,ASTM D648.
Features : Advanced Control System With super high stability, it is easier to install, test and analyze. 3.Humanized Software Control System Simulated digital tube displays temperature and displacement, draws test curves, provides a variety of coordinate curves, centralizes data management, and can analyze test data, print test curves, test data and test reports. 4.Four-fold safety protection of condyle Mechanical temperature upper limit protection switch, software temperature upper limit protection, automatic test stop and administrator operating keys and other multiple hardware and software safety design, to ensure the safe and stable operation of the test. 5.High Precision Measurement and Control System High performance temperature sensor and advanced capacitive grating digital micrometer are used to accurately measure the small changes of the sample. Advanced PID algorithm and all-photoelectric isolation phase modulation module are used to control the temperature rise, which ensures that the temperature rise rate error is less than 0.5 C.
Technical Parameters: The temperature control range: room temperature ~ 300 °C; Maximum temperature error: ± 0.5 °C; Temperature rising speed: 50 C/h, 120 C/h, or between 50 and 120 C/h; Temperature measurement point: 1; Number of test frames: 3; Deformation measuring instruments: high precision digital display micrometer; Deformation measurement range: - 0.1-10 mm; Maximum deformation error: +0.005mm; Deformation resolution: 0.001 mm; Supporting span of specimen: 64mm, 100mm; It has software upper limit temperature protection function and hardware upper limit temperature protection function (temperature switch imported from Korea, with current of 30A, not pseudo protection, heating power of 4000W, can ensure temperature rise to 300 degrees at 120 C/h speed) The thermal expansion coefficient of the specimen frame is less than0.005 / 100 °C(emphasis, directly affecting experimental results); MCU and PC distributed control system are adopted in the control mode. Use medium: methyl silicone oil or transformer oil; Cooling mode: natural cooling above 150 C, water cooling below 150 C or natural cooling. Test frame lifting method: Manual.